How to make a correct calculation of a warm water floor?

click fraud protection

Warm floors gained enough popularity is well deserved - not only do they make the accommodations comfortable and cozy, it is also a cost-effective calculation: warm water floor enough to heat any room, not just often associated with it bathroom.The technology is equally effective for all types of buildings and structures.The system is universal, ie it is possible to build both during construction and mounted to the finished object.In this heat loss is practically reduced to a minimum: the circulation of hot water under the floor heats the air as efficiently as possible and gives comfort beloved home.Calculation of warm water floor, done correctly, will save on heating, avoid wasting.This is the most effective system to date heating an apartment or house.Among its benefits can still be attributed with certainty that it does not take useful space, and does not create electromagnetic fields (like electric underfloor heating), which are especially dangerous for men.

essence of the water floor heating is covered in several positions:

  1. screed mounted on the main pipeline network for the circulation of water, then finish tie, and top - floor.
  2. hot water heats the floor, which in turn distributes the heat evenly up, eliminating the presence of overheated zones (as is the case with radiators) and drafts (air movement in the horizontal is simply impossible).
  3. can be created for each room its own climate, set the desired temperature on the thermostat or climate compensator.

Proper design will allow water heating to avoid problems (insufficient temperature or overheating, difficulty adjusting mode).This will require to calculate the heating load for individual rooms.To have a reliable Heated floor, it requires a quality performance of 3 points: the calculation equipment, installation.

Calculation of warm water floor plan assumes knowledge of housing sizes and types of windows, floor coverings, wall material, as well as their type outside the location of the heat generator and collectors.

preferred embodiment of the pipe laying is considered a "snail", which, in contrast to the "snake", saving up to 15% of the material (the actual pipe) and a winning performance by hydraulics.

Water or floors can be used as an additional source of heating or as the principal - it all depends on the results of the calculation.It is important to take into account the constraints: temperature permitted in a residential area above the surface should not exceed 26 C, and in the non-residential premises, such as in the bath or shower - 32 C. If the calculation of hot water floor will compensate for the loss of heat and do not go beyond that, you canrestrict this heating system.And if not, what is required addition radiators.However, regardless of the calculation of a reasonable combination of the two autonomous systems - in the case of cold weather, for example.