Gasoline Generators Inverter vary by type of engines.They use four-stroke engines and two.The fuel is a mixture of gasoline and industrial oils.The amount of time to failure in two-stroke engines in the range of 500 hours.Accordingly, such a generator gasoline inverter is useful only in the country where it is necessary to provide coverage that includes a few light bulbs or outings.Therefore, these types of power plants are not widely spread.
four-stroke gasoline generator inverter DDE
European and American manufacturers aiming to produce power with four-stroke engines.This gasoline generator inverter DDE, belonging to the class of "professional".Camshaft them is in the lower position and the operation time is in the range of 8 hours for one day.Automation is used to stop the engine while reducing the number of technical oils.This sturdy plant.According to passport data, they ensure trouble-free running time for 3000-4000 hours.
Continuous operation and the capacity of the fuel tank
These values are interrelated.From the fuel tank and the tank where it is stored, it depends on how long the generator gasoline inverter will not be interrupted and will continue to generate electricity.Discussing this feature, it should be recalled that do refueling of the fuel tank in operating condition is unacceptable.It should shed a little oil or gasoline - and the risk of fire will be too high.
In those situations, when the need for long-term continuous operation of the power plant is very large, it is advisable to install an additional or reserve fuel tank.But here it should be noted that the total daily duration of work may not exceed for most models of 8 hours, and for some - 10 hours.From this mode, reliance on oil change intervals of 50 hours.If gasoline inverter generator is operated only once or twice a week, and only 2 hours, replace the oil filter and the oil must be done every 150 hours.Taking into account national peculiarities of our market, we should not adhere to these standards.To the machine worked long and well, and the oil filter is better to change earlier period specified in the instructions and carefully chosen oil.And to a backup fuel tank should attach more filter that will separate from the gasoline and water impurities.
transition from 220 to 380
choosing gasoline generator inverter for a country house or manufacture of single-phase consumption, should give preference to the single-phase power.However, based on the fact that their power is limited to 30 kW, this may be insufficient.
If you have equipment that requires three-phase current, then you need to buy and the corresponding power station, but in order to align the load, it is necessary to make the division of power into three lines.This is very important because the three-phase generators are highly sensitive to distortions in phases.But if the power consumption of the equipment is small, it is better to give preference to the single-phase station having a system that combines phase.Then the generator will operate in the 220, and, if necessary, will go to the mode of 380 V.